41L Single Compartment Mobile Fridge/Freezer AC/DC - Stainless Steel

The SnoMaster – 41L Single Compartment Mobile Fridge/Freezer AC/DC – Stainless Steel (SMEX-41S) is compact, durable, and Designed For African Conditions. With a wide temperature range from -20°C to 10°C, built-in LED light, digital display, and soft-closing lid, this single-compartment unit is perfect for camping, road trips, and everyday outdoor adventures.

Product Features:

2-Speed Setting - Max & Eco

Airtight Lid Seal

Internal AC/DC Power Supply

Includes Basket

Low Voltage Cut-Out Setting (9.6, 10.8, 11.4V)

Corner Feet With Mounting Holes

Durable Plastic Handles

Make it yours:

R10,999.00
*Recommended Retail Price
  • Dimensions (mm) Unit: (H) 500 (W) 364 (D) 716
  • Dimensions (mm) Packaged: (H) 554 (W) 419 (D) 777
  • Storage Volume: 41 Litres (65 x 300ml Beverage Cans)
  • Temp Range: -20°C to 10°C
  • Rated Current AC: 0.68A at AC 240V
  • Rated Current DC: 6.75A at DC 12V | 3.48A at DC 24V
  • Voltage: Voltage AC: 220V Voltage DC: 12V/24V
  • Net Weight: 19.3Kg
  • Compressor 65W
  • Insulation: Cyclopentane
  • Colour: Stainless Steel
  • Note: All dimensions include handles and hinges. Maintain a 150mm clearance around the unit, ensuring adequate air circulation. Avoid tilting the appliance more than 45 degrees from its upright position.

Unboxing & Set-up

Product Gallery

FAQ
Why Is My SnoMaster - 41L Single Compartment Mobile Fridge/Freezer DC With 220V Power Adapter - Stainless Steel (SMEX-41S) Displaying Error Code E1?

Error Code E1: Low Voltage Protection

The appliance has detected insufficient supply voltage.

Possible Causes:

  • Battery voltage is too low.
  • Poor vehicle power supply.
  • Modified or undersized DC wiring.
  • Damaged power cable.

What To Do:

  • Connect the appliance to an alternative power source.
  • Check the battery condition and charge level.
  • Verify the Low Voltage Cut-Off setting.
  • Inspect the power cable for damage.
  • If wiring has been extended, ensure the cable thickness is suitable for the increased length.

 

Why Is My SnoMaster - 41L Single Compartment Mobile Fridge/Freezer DC With 220V Power Adapter - Stainless Steel (SMEX-41S) Displaying Error Code E2?

Error Code E2: Fan Fault

The cooling fan is not operating correctly.

Possible Causes:

  • Fan motor failure.
  • Fan drawing excessive power.
  • Fan obstruction.

What To Do:

  • Check for obstructions around the fan area.
  • Restart the appliance.
  • Contact SnoMaster or a SnoMaster-approved technician or service agent if the error remains.

 

Why Is My SnoMaster - 41L Single Compartment Mobile Fridge/Freezer DC With 220V Power Adapter - Stainless Steel (SMEX-41S) Displaying Error Code E3?

Error Code E3: Compressor Start Failure

The compressor cannot start correctly.

Possible Causes:

  • Unstable power supply.
  • Compressor fault.
  • Compressor controller fault.
  • Power supply fault.

What To Do:

  • Switch the appliance off and disconnect power.
  • Wait approximately 10 minutes before restarting.
  • Test using another power source.
  • If the error persists, contact a service agent.

 

Why Is My SnoMaster - 41L Single Compartment Mobile Fridge/Freezer DC With 220V Power Adapter - Stainless Steel (SMEX-41S) Displaying Error Code E4?

Error Code E4: Low Compressor Speed

The compressor is unable to maintain the required operating speed.

Possible Causes:

  • Appliance is overpacked.
  • Restricted airflow around the compressor.
  • High ambient temperatures.
  • Fan fault.

What To Do:

  • Remove excess contents from the appliance.
  • Ensure ventilation openings are unobstructed.
  • Move the appliance to a cooler location.
  • Keep the appliance out of direct sunlight.

 

Why Is My SnoMaster - 41L Single Compartment Mobile Fridge/Freezer DC With 220V Power Adapter - Stainless Steel (SMEX-41S) Displaying Error Code E5?

Error Code E5: Compressor Overheating

The compressor has exceeded its safe operating temperature.

Possible Causes:

  • High ambient temperature.
  • Poor ventilation.
  • Fan fault.
  • Blocked air vents.

What To Do:

  • Move the appliance to a cooler area.
  • Ensure adequate airflow around all ventilation openings.
  • Clean any dust or debris from the vents.
  • Keep the appliance out of direct sunlight.