Possible Causes:
The unit is unplugged.
The power switch is off.
The fuse or circuit breaker has tripped.
The ice-storage bin is full.
Solutions:
Plug the SM-250 into a working power outlet.
Switch on the unit at the control panel.
Check and reset the fuse or circuit breaker.
Remove excess ice from the storage bin and restart the machine.
Possible Causes:
Water tap is closed.
Inlet pipe is loose or incorrectly connected.
Water pressure is too low or inlet filter is blocked.
Solutions:
Turn on the water supply.
Reconnect or tighten the inlet pipe securely.
Check water pressure (should be 2 – 4 Bar) and clean or replace the inlet filter.
Possible Causes:
Condenser is dirty or airflow is blocked.
Poor ventilation around the machine.
Ambient or water temperature is too high.
Solutions:
Clean the condenser regularly to maintain efficiency.
Ensure the SM-250 has sufficient space for airflow.
Keep the unit away from direct sunlight or heat sources.
Possible Causes:
Insufficient water flow or pressure.
Blocked water line or filter.
Water temperature is too warm.
Solutions:
Inspect the water line for kinks or blockages.
Confirm correct water pressure between 2 – 4 Bar.
Use cooler incoming water to stabilise production.
Possible Causes:
Drain pipe is loose or not properly connected.
Condensation forming on the unit surface.
Internal hose connection is loose.
Solutions:
Tighten or reconnect the drain pipe securely.
Wipe away normal condensation from the exterior.
Inspect internal hose fittings and reseal if necessary.